Autocon Technologies Delta 40-MU with Disc Drive CNC System
Repair
Call for price
Purchase
CSL Part Number: 87682
Product Overview: A PC-based CNC control assembly that manages machine tool motion and program execution for milling, turning, and other automated machining equipment. It runs under DOS, boots from a 1.44MB floppy drive, and stores operating programs on an onboard flash memory card.
Category: Control Assembly
Manufacturer: Autocon Technologies
Manufacturer Part Number: Delta 40-MU with Disc Drive
Common Failures
Two main issues have been observed: boot errors related to the floppy drive and issues with the Flash Memory Card. Specific observed failures have included a melted floppy drive power connector and improperly seated or damaged components on the Flash Memory Card.
Repair Approach
For boot errors related to the floppy drive, repairs have involved replacing the floppy drive and its power connector. In cases involving the Flash Memory Card, repairs have included straightening bent pins and properly reseating the card components.
Testing & Quality
Repairs are verified by ensuring the unit successfully boots using a test floppy disk and the Flash Memory Card. Additional tests may include extended runs to confirm stability and proper function.
Repair your broken Autocon Technologies part
We can repair your Autocon Technologies model Delta 40-MU with Disc Drive .
Please note: our repair turnaround time may be longer than our standard lead times for this item.
Step 1 -
Click the green button above, "Repair Now," and add to your RMA.
Step 2 -
Print the RMA form that is emailed to you, and put it in a box with the parts for repair.
Step 3 -
Mail the box to the address on the RMA.
You will be sent an authorization for repair via email. Your approval is needed before any work is started.
Once the user has seen at least one product this snippet will be visible.