Baldor Electric ID10202-E Series 10, 2 HP 230VAC with Keypad
Repair
Repair Price: $ 1,684.00
Purchase
CSL Part Number: 33493
Product Overview: The Baldor Electric ID10202-E is a 2 HP, 230VAC AC inverter drive from the ID 10 Series, equipped with an integrated keypad for parameter programming and control. This variable frequency drive regulates the speed and torque of three-phase AC induction motors by converting fixed-frequency AC power to variable-frequency output. It is commonly used in industrial automation, conveyor systems, pumps, fans, and machine tools where precise motor speed control is required. The keypad allows local configuration of operating parameters including acceleration/deceleration rates, frequency limits, and motor protection settings.
Category: AC Motor Controls
Manufacturer: Baldor Electric
Manufacturer Synonyms: ABB
Manufacturer Part Number: ID10202-E
Series: ID 10 Series AC Inverter
Common Failures
Devices have been received for evaluation with symptoms such as lightning damage and non-functionality. Some units described as functional prior to shipment fail to operate when received, which may indicate internal issues.
Repair Approach
When a device is received, a thorough inspection is conducted to identify potential faults. In some cases, units show no apparent physical damage but fail functional tests. Diagnostic testing and attempts to reset to factory settings may be performed to determine if programming issues are present. When deeper module-level issues are found, the unit may be beyond economical repair.
Testing & Quality
Diagnostic testing is carried out to evaluate the condition of the unit and determine next steps. Units are inspected and tested to assess whether programming issues can be resolved through reset procedures. However, units with extensive lightning damage or internal module failures may not be economically repairable and would be returned with our findings and recommendations.
Service and repair your broken Baldor Electric part
We can repair your Baldor Electric model ID10202-E in our facility. Let our skilled technicians get your Baldor Electric back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.