Conair 107-606-01 MLC-6 Loader Control 120VAC
Repair
Repair Price: $ 494.00
Purchase
CSL Part Number: 31522
Product Overview: The MLC-6 Loader Control is a 120VAC programmable control unit manufactured by Conair for automated material handling systems. It manages vacuum hopper loaders commonly used in plastics processing and manufacturing environments to transfer pellets or powder from storage containers to processing equipment. The controller sequences loader motor operation, monitors fill sensors, and controls outputs including purge, blow-back, air discharge, and alarm functions. It features a keypad interface for programming load times, ratios, and operating parameters. The unit uses triac-based output switching to control various pneumatic and motor functions, with multiple fused circuits protecting sensor supply voltage and output stages.
Category: Operator Interface
Manufacturer: Conair
Manufacturer Synonyms: IPEG, Franklin
Manufacturer Part Number: 107-606-01
Series: MLC 6 Loader Control
Also Known As(AKA): MLC6-120
Additional charges may apply if gooseneck wiring, display or keyboard is damaged. Send your unit in for evaluation.
Common Failures
Common issues with this product include failure to recognize load demand, no load output, stuck load outputs, and defective keypads. Other reported problems are related to shorted TRIACs causing stuck output stages, high equivalent series resistance in capacitors, missing or blown fuses, incorrectly keyed connectors, and issues with proximity sensors and connectivity.
Repair Approach
Repairs often involve replacing defective components such as TRIACs, capacitors, keypads, and fuses. In cases where components are irreparable or unavailable, units may be classified as Beyond Economic Repair. Corrective measures also include addressing connectivity issues by replacing output cables and correcting misconfigured connectors. For some units, reprogramming may be necessary after replacing keypads or components.
Testing & Quality
Repaired units are subject to diagnostic tests and burn-in tests to verify functionality. Testing confirms the ability to cycle through various operational sequences, including load, purge, and alarm functions. Units are tested to ensure all outputs work as intended and that each device can run its program correctly. Repairs are cross-validated by multiple technicians to ensure quality and reliability.
Service and repair your broken Conair part
We can repair your Conair model 107-606-01 in our facility. Let our skilled technicians get your Conair back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.