Danfoss 175Z4012 VLT 5008 200-240V 32A 5.5KW 7.5 HP 0-1000 Hz AC Drive
Repair
Repair Price: $ 2,312.00
Purchase
CSL Part Number: 76500
Product Overview: An AC variable frequency drive that controls the speed and torque of three-phase AC motors by varying output frequency and voltage. Rated for 200-240V input, 32A, 5.5 kW (7.5 HP), with an output frequency range of 0-1000 Hz. Used in industrial motor control applications.
Category: DC Motor Controls
Manufacturer: Danfoss
Alternate Manufacturer Names: VLT 5008 P T2 C54 ST R0DL
Manufacturer Part Number: 175Z4012
Series: VLT5000 series
Other Synonyms: VLT 5008 P T2 C54 ST R0DL
Common Failures
Units submitted for evaluation frequently exhibit issues related to the IGBT or power card, which can impact control functionality.
Repair Approach
Repairs may involve the replacement of components such as capacitors and fans. The gate circuit board and individual gate circuits on the control board may also require repair work involving surface-mount technology components.
Testing & Quality
Each repaired unit undergoes testing to verify output at 60Hz to the motor. A final testing phase of five hours is standard following repair work.
Service and repair your broken Danfoss part
We can repair your Danfoss model 175Z4012 in our facility. Let our skilled technicians get your Danfoss back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.