Product Overview: A data acquisition controller that collects, monitors, and stores process data from industrial machinery during operation. It features nonvolatile RAM for retaining configuration and recorded data, and supports continuous run-mode monitoring. Commonly applied in plastics processing and injection molding production environments.
Category: Data Acquisition
Manufacturer: Hunkar
Manufacturer Part Number: 60620DACIII
```html
Common Failures
Two recurring issues have been identified with this product: failure to update and loss of functionality, alongside display failures. Both problems were traced back to NVRAM components. In each case, NVRAM replacement was necessary to restore proper function.
Repair Approach
The solution involved replacing the NVRAM and ensuring that the original data was accurately transferred to the new component. This approach confirmed that data integrity was maintained post-repair.
Testing & Quality Assurance
After replacing the NVRAM, extended testing, including overnight burn-in, was conducted to verify that the repairs were serviceable. These tests confirmed that the devices operated correctly with no subsequent failures.
```We do NOT offer repair on this item
Unfortunately, Control System Labs does NOT offer repair for the Hunkar part number . Here are some possible reasons:
- the parts may no longer be available
- the item may be encased in plastic epoxy
- we do not have the necessary equipment to do the repair.
Please contact the manufacturer of this part number to see if a new part number or compatible replacement is available.