LH Research TMA24-1335/115 Quad Output Power Supply, 225W
Repair
Repair Price: $ 536.00
Purchase
CSL Part Number: 51439
Category: Power Supply
Manufacturer: LH Research
Manufacturer Part Number: TMA24-1335/115
Series: TMA Series Switching Power Supply
Power supplies are tested with a minimum 4-hour burn-in, under load.
Common Failures
A frequently encountered issue with this power supply is the output not meeting the specified voltage levels. Specifically, the power supply may output +/- 9v instead of the expected +/-15v, and 5v instead of 24v. This can be caused by corrosion and damaged traces on the board.
Repair Approach
Repair of these units may involve replacing capacitors and addressing board-level damage. If the damage is extensive, particularly in cases with severe corrosion and multiple damaged traces, the unit may be evaluated as Beyond Economic Repair (BER). We would be glad to review the item and provide a quotation before any repair work begins.
Service and repair your broken LH Research part
We can repair your LH Research model TMA24-1335/115 in our facility. Let our skilled technicians get your LH Research back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.