CSL Part Number: 87023
Product Overview: The T300 Series Remote Controller by Omnex is a wireless handheld transmitter used to remotely operate heavy equipment such as Vactor vacuum trucks and Carlton Hurricane stump grinders. It features a joystick, multiple paddles with hall effect sensors, toggle switches, potentiometers, and an emergency stop function. The unit communicates in the 900-930 MHz RF range and can operate via wireless or tether connection. It is powered by batteries and includes calibration capability for analog control inputs.
Category: Transmitter
Manufacturer: Omnex
Manufacturer Part Number: T300-000422 Rev F
Series: T300 Series Remote

Common Failures

Units received for evaluation have exhibited intermittent power issues due to poor connections, faulty joysticks preventing control operations, and non-functional paddle controls due to defective sensors. Physical damage from impacts, such as falling off vehicles, may cause internal fractures and misalignment of components. E-stop contact failures and calibration challenges in paddle and joystick assemblies have also been observed.

Repair Approach

When a unit is determined to be serviceable, repair procedures may involve re-crimping electrical connections for improved power delivery, replacing defective components such as joysticks and hall effect sensors, and addressing physical damage by restoring mechanical integrity. Paddle repairs may require replacing photointerruptors and recalibrating sensors. In cases of impact damage, repairs may include reinforcing or replacing plastic housings and correcting signal trace fractures on internal PCBs.

Testing & Quality Assurance

After repairs are completed, testing is conducted to verify functionality. This may include verifying communication via RF analyzers, conducting burn-in tests, and performing operational tests with diagnostic receivers. Units are calibrated to ensure control response from switches, joysticks, and sensor assemblies. Final testing verifies that wireless and tethered operations meet performance standards.

Service and repair your broken Omnex part


We can repair your Omnex model T300-000422 Rev F in our facility. Let our skilled technicians get your Omnex back in operation quickly.


Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.

Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.

Step 3 - Ship or mail the box to the address listed on the RMA.

This is a preview of the recently viewed products by the user.
Once the user has seen at least one product this snippet will be visible.

Recently viewed Products