Product Overview: The Reliance Electric 707973-10T is a field current regulator assembly used in DC motor control systems. It regulates field current for DC motors by controlling SCR-based power delivery, providing precise motor speed and torque control. Commonly found in industrial paper machinery and other heavy-duty applications requiring variable speed DC drives, it interfaces with Reliance FlexDrive systems. Key components include a dual SCR power module, LEM current transducer for feedback, control circuitry, and transformers for isolated power supplies.
Category: Motor Controls
Manufacturer: Reliance Electric
Manufacturer Part Number: 707973-10T
Series: Field Current Regulator
Also Known As(AKA): 911FK0151 NEW P/N
Common Failures
Common symptoms reported include unexplained faults when driving on hard stops and rapidly fluctuating current readings. Another issue involves field loss indications on the regulator board.
Repair Approach
We evaluate each unit to determine the root cause. Typical repairs may involve replacing the current transducer module when unexplained drive faults are present. For field loss problems on the regulator board, replacing the SCR module may be effective. Diagnostic testing and inspection are performed to isolate faulty components.
Testing & Quality
Repaired units are tested after components are replaced. Testing procedures include functional checks to verify that current output matches expected values under various drive conditions. Units that pass all testing phases are cleared for return to service.
Service and repair your broken Reliance Electric part
We can repair your Reliance Electric model 707973-10T in our facility. Let our skilled technicians get your Reliance Electric back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.