Common Failures

Several common issues have been identified in the repair history of this product. These include phase loss faults due to defective power supply capacitors, physical damage to connectors and LEDs, and issues related to overheating components such as burned bus connections and circuit board arcing. In some cases, capacitors were found tilted, leaking, or degraded, contributing to performance issues. Additionally, the failure of cover clips, leading to short circuits, has been noted.

Repair Approach

The repair process typically involves replacing defective components, including capacitors, connectors, fans, and resistors. Damaged traces and burnt circuit boards are repaired. In cases where physical damage is evident, repairs include replacing covers and missing fasteners. Preventive replacements of certain components such as PWM chips may also be conducted to improve reliability.

Testing & Quality

After repairs, testing is performed to verify proper operation of the unit. This includes verifying DC supplies, checking for successful power-up operations, and extended operational testing to evaluate reliability. Units are connected to appropriate power loads and observed for correct LED indications to confirm that repairs have been completed.

Service and repair your broken Reliance Electric part


We can repair your Reliance Electric model PSM-125 TYPE BRU-500 in our facility. Let our skilled technicians get your Reliance Electric back in operation quickly.


Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.

Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.

Step 3 - Ship or mail the box to the address listed on the RMA.

This is a preview of the recently viewed products by the user.
Once the user has seen at least one product this snippet will be visible.

Recently viewed Products