Common Failures
Some units may exhibit intermittent start-up issues, where operation occurs for a period and then stops. This is among the conditions we can evaluate and address during repair.
Repair Approach
Our technicians address intermittent start-up issues through a range of methods, which may include reseating connectors, cleaning integrated circuit pins with a deoxidizer, and cleaning fans and capacitors. Additional troubleshooting may include verifying the functionality of the pump diode laser, RF modulator, and other key components. Proper cleaning and secure connections are important factors in addressing these conditions.
Testing & Quality
After repairs, we conduct multiple tests to verify reliable operation. Testing may include running the unit with a test load and verifying the functionality of various external pinouts and sensors such as the aiming diode and XTAL temperature sensor. This thorough testing process is designed to confirm that the unit meets our quality standards before it is returned.
Service and repair your broken Telesis part
We can repair your Telesis model XP1 in our facility. Let our skilled technicians get your Telesis back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.