Product Overview: The Warner Electric MCS-166 is a plug-in module power supply that converts 24V AC input to 24V DC output for industrial control applications. Commonly used in paper manufacturing equipment and other Warner Electric control systems, it features a compact modular design for easy installation and replacement. The unit includes a transformer, bridge rectifier, filter capacitors, and protective fusing. It can be configured for either 120V or 240V AC primary input via selector switch and delivers regulated DC output suitable for powering control circuits, sensors, and actuators in automated machinery.
Category: Power Supply
Manufacturer: Warner Electric
Manufacturer Synonyms: Seco, Altra Industrial Motion
Manufacturer Part Number: MCS-166
Power supplies are tested with a minimum 4-hour burn-in, under load.
Common Failures
Common issues with this product include transformer damage, shorted bridge rectifiers, and defective solder joints. High ESR in capacitors and shorted zener diodes have also been frequently observed.
Repair Approach
Our team evaluates each unit individually. Repairs may involve resoldering connections, replacing defective components such as rectifiers and capacitors, and restoring mechanical integrity when physical damage is noted. We address fuses, diodes, and other components as needed based on the findings from our evaluation.
Testing & Quality
After repairs are completed, each unit undergoes comprehensive testing, including burn-in tests with a digital load. Output voltage is verified to confirm proper operation. All repairs are reviewed by our technicians to ensure quality standards are met.
Service and repair your broken Warner Electric part
We can repair your Warner Electric model MCS-166 in our facility. Let our skilled technicians get your Warner Electric back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.
Once the user has seen at least one product this snippet will be visible.