Barber-Colman A-12240 Maco IV Parison Control 2 Card PC2
Repair
Repair Price: $ 480.00
Purchase
CSL Part Number: 16535
Product Overview: Parison control card for blow molding machine controllers, managing parison wall thickness programming and coordinating mold and hydraulic pressure circuits. Part of a modular process control system used in plastics manufacturing, it interfaces via P2 and edge connectors and operates alongside a companion PC1 board.
Category: Barber Colman MACO Controls
Manufacturer: Barber-Colman
Manufacturer Synonyms: Barber Coleman, Barbercolman, Invensys
Manufacturer Part Number: A-12240
Series: MACO IV
Brand: Barber-Colman
Also Known As(AKA): PC2 CARD
Common Failures
Common issues reported include broken pins on the P2 connector and system errors such as "NODMA" or "System call error/no DMA." Some units have also exhibited broken capacitor leads associated with control problems.
Repair Approach
Repairs typically involve replacing broken pins on connectors and repairing or replacing damaged components such as capacitor leads. The repair process also includes cleaning and verifying the edge connectors to ensure proper connections and functionality.
Testing & Quality
Units undergo testing following repairs, which may include running hydraulic pressure circuits, extended operational tests, and computer test jig verifications. These measures help confirm that units are functioning correctly before being returned.
Service and repair your broken Barber-Colman part
We can repair your Barber-Colman model A-12240 in our facility. Let our skilled technicians get your Barber-Colman back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.