Common Failures

Units evaluated have shown issues including voltage drift, particularly in the 100-volt range. Reported concerns include erratic output in positive polarity within this range and general drift from set voltage levels. Calibration-related concerns have also been observed.

Repair Approach

Repairs have typically involved replacement of components such as potentiometers, capacitors, transistors, and resistors as identified during evaluation. Following component replacement, recalibration of voltage ranges and burn-in testing are performed.

Testing & Quality

Units undergo burn-in testing post-repair, ranging from 2 to 40 hours at various voltage levels, to verify stable performance. Calibration checks and verification procedures are performed before units are returned.

Service and repair your broken Data Precision part


We can repair your Data Precision model 8200 RT2 in our facility. Let our skilled technicians get your Data Precision back in operation quickly.


Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.

Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.

Step 3 - Ship or mail the box to the address listed on the RMA.

This is a preview of the recently viewed products by the user.
Once the user has seen at least one product this snippet will be visible.

Recently viewed Products