Halmar Robicon 1PCI-48120-CL/OC-D-ER4 480V 120 Amp SCR Power Controller
Repair
Repair Price: $ 1,332.00
Purchase
CSL Part Number: 120809
Product Overview: The Halmar Robicon 1PCI-48120 is a single-phase SCR power controller rated for 480V at 120 amps. It provides proportional power control to resistive loads by phase-angle firing of silicon-controlled rectifiers. Common applications include industrial heating elements in paper processing and manufacturing equipment. The unit features adjustable bias, gain, and current limiting controls, accepts analog input signals for remote control, and uses a 150 fuse for protection. It belongs to Halmar's 1PCI series of single-phase power controllers.
Category: Power Controls
Manufacturer: Halmar Robicon
Manufacturer Synonyms: Robicon
Manufacturer Part Number: 1PCI-48120-CL/OC-D-ER4
Series: 1PCI Single Phase Power Controller
Missing or bad fuses additional.
Common Failures
Frequently reported issues for this product include blown fuses and loss of output. These problems may be related to capacitors, fuses, or other internal components. In some cases, further evaluation is needed to identify the underlying cause.
Repair Approach
Our repair process typically involves component replacement and diagnostic testing to identify the root cause. Once the unit is received and evaluated, we can provide a quotation before any repair work begins. Repairs may include capacitors, power modules, transformers, and other components as needed based on our technical review.
Testing & Quality
Following repairs, each unit undergoes testing procedures that include load testing and functional verification. We test output controls, verify voltages, and check for proper operation to ensure the repaired unit meets our quality standards.
Service and repair your broken Halmar Robicon part
We can repair your Halmar Robicon model 1PCI-48120-CL/OC-D-ER4 in our facility. Let our skilled technicians get your Halmar Robicon back in operation quickly.
Step 1 - Click the green 'Repair Now' button above to add the part and then complete the RMA.
Step 2 - The RMA form will be sent to you via email. Print the RMA form and put it in a box with the item(s) for repair.
Step 3 - Ship or mail the box to the address listed on the RMA.
Once the user has seen at least one product this snippet will be visible.